Desincrustante fuertemente ácido no espumante

Nitracip Pro

Nitracip Pro, Desincrustante fuertemente ácido no espumante

Español

Producto fuertemente ácido de alto poder desincrustante y desoxidante. Especialmente formulado para la limpieza en circuitos y sistemas CIP en la industria alimentaria. Elimina las incrustaciones calcáreas producidas por la dureza del agua, depósitos de suciedad mineral y residuos que dejan los detergentes alcalinos.

Dosis y forma de empleo
Para limpieza por recirculación, enjuagar previamente con agua y a continuación hacer circular el producto a una concentración de 0.5 - 1 % durante unos 15 - 20 min. Temperatura entre 40 - 60 ºC. Finalmente aclarar con agua abundante. Por inmersión, dosis de entre 1 - 5 % a una temperatura entre 40 - 60 ºC. Aclarar con agua abundante.
Datos técnicos
Aspecto: Líquido incoloro transparente.
pH (1%): 1.5 +/- 0.5
Densidad (20ºC): 1.27 +/- 0.03 g/ml
Componentes principales
Contiene ácido nítrico.
Presentación
25 kg, 1200 kg.
Precauciones de utilización o manipulación
NO INGERIR
H290 Puede ser corrosivo para los metales.
H331 Tóxico en caso de inhalación.
H314 Provoca quemaduras graves en la piel y lesiones oculares graves.
EUH071 Corrosivo para las vías respiratorias.
P102-P405 Mantener fuera del alcance de los niños. Guardar bajo llave.
P280 Llevar guantes, prendas y gafas de protección. En caso de ventilación insuficiente, llevar equipo de protección respiratoria.
P363 Lavar las prendas contaminadas antes de volver a usarlas.
P303+P361+P353 EN CASO DE CONTACTO CON LA PIEL (o el pelo): Quitar inmediatamente toda la ropa contaminada. Enjuagar la piel con agua [o ducharse].
P305+P351+P338 EN CASO DE CONTACTO CON LOS OJOS: Enjuagar con agua cuidadosamente durante varios minutos. Quitar las lentes de contacto cuando estén presentes y pueda hacerse con facilidad. Proseguir con el lavado.
P403+P233 Almacenar en un lugar bien ventilado. Mantener el recipiente cerrado herméticamente.
P501 Eliminar el contenido/el recipiente de conformidad con la normativa local.
No mezclar con otros productos químicos.
Revisión:
3
Fecha:
19/01/2023

English

It is a highly effective and strongly acidic product, specially formulated for cleaning in circuits and CIP systems in the food industry. Designed to remove limescale deposits caused by water hardness, as well as mineral dirt deposits and residues left by alkaline detergents.

With its high descaling and deoxidising power, it guarantees efficient and thorough cleaning. This product is ideal for removing stubborn deposits and residues that accumulate in circuits and CIP systems, thus maintaining optimum performance and impeccable hygiene in the food industry.

The dosage and method of use are simple and effective. For cleaning by recirculation, it is recommended to first rinse with water and then circulate the product at a concentration of 0.5 to 1% for approximately 15 to 20 minutes, at a temperature between 40 and 60 °C. Finally, rinse with plenty of water. In the case of immersion cleaning, a dosage of 1 to 5 % is used at a temperature between 40 and 60 °C, followed by thorough rinsing with water.

The main component of this product is nitric acid, known for its high efficiency in removing scale and residues.

It is available in 25 kg and 1200 kg packages, allowing for easy handling and storage in different industrial environments.

It is a highly effective and strongly acidic product, specially formulated for cleaning in circuits and CIP systems in the food industry. Designed to remove limescale deposits caused by water hardness, as well as mineral dirt deposits and residues left by alkaline detergents.

With its high descaling and deoxidising power, it guarantees efficient and thorough cleaning. This product is ideal for removing stubborn deposits and residues that accumulate in circuits and CIP systems, thus maintaining optimum performance and impeccable hygiene in the food industry.

The dosage and method of use are simple and effective. For cleaning by recirculation, it is recommended to first rinse with water and then circulate the product at a concentration of 0.5 to 1% for approximately 15 to 20 minutes, at a temperature between 40 and 60 °C. Finally, rinse with plenty of water. In the case of immersion cleaning, a dosage of 1 to 5 % is used at a temperature between 40 and 60 °C, followed by thorough rinsing with water.

The main component of this product is nitric acid, known for its high efficiency in removing scale and residues.

It is available in 25 kg and 1200 kg packages, allowing for easy handling and storage in different industrial environments.

Dosage and use instructions
For recirculation cleaning, rinse previously with water and then circulate the product at a concentration of 0.5 - 1 % during 15 - 20 min. Rinse with plenty of water afterwards. By immersion, dosage between 1 - 5 % at a temperature of 40 - 60 ºC. Rinse with plenty of water.
Technical data
Appearance: Transparent colourless liquid.
pH (1%): 1.5 +/- 0.5
Density (20ºC): 1.27 +/- 0.03 g/ml
Main components
Contains nitric acid.
Presentation
25 kg, 1200 kg.
Use or handling precautions
DO NOT SWALLOW
H290 May be corrosive to metals.
H331 Toxic if inhaled.
H314 Causes severe skin burns and eye damage.
EUH071 Corrosive to the respiratory tract.
P102-P405 Keep out of reach of children. Store locked up.
P280 Wear protective gloves, clothing and eye protection. In case of inadequate ventilation wear respiratory protection.
P363 Wash contaminated clothing before reuse.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P403+P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container in accordance with local regulations.
Do not mix with other chemichals.
Review:
3
Date:
19/01/2023